Zhengzhou Zhonglian Cable Co., Ltd.
Products
Contact Us
  • Contact Person : Ms. Du Alicia
  • Company Name : Zhengzhou Zhonglian Cable Co., Ltd.
  • Tel : 86-371-67857182
  • Fax : 86-371-67857333
  • Address : Henan,zhengzhou,No. 666 Zhongyuan West Road, Zhongyuan District, Zhengzhou
  • Country/Region : China
  • Zip : 450042

450/750V PVC sheath control cable XLPE insulation

450/750V PVC sheath control cable XLPE insulation
Product Detailed
Related Categories:Control Cables
Control Cable are suitable for the connection of controlling electrical equipments and instrument meters,monitoring .....

450/750V or lower control cable XLPE insulation and PVC sheath

Rated Voltage: Rated voltage: 450/750V

XLPE insulated and PVC sheathed control cable are manufactured according to National Standard GB933088 which is drawn up by reference to IEC 227 and IEC 502 as well as the standards of Germany, America, Janpan and so on. For control cable can be manufactured special control cable according to other standards or requirement of customers.

 

Product Description

 

1. Standard The products can be produced according to the standard GB9330-1988, and the factory can also manufacture the cable with other standards.

2. Scope of Application The products are suitable for the connection of controlling electrical equipments and instrument meters, monitoring and controlling return circuit, protecting and measuring in power distribution unit under the circumstance that the rated voltage is up to 450/750V AC.

3. Type & Specification

Type Name /Section Area(mm2)/ No. Of core/ Application Site KVV

Copper Conductor, PVC Insulated and Sheathed Control Cable

0.75, 1.0, 1.5, 2.5

2-16

Permanent installation indoors, incable ditches or plpes

 

Type Name /Section Area(mm2)/ No. Of core/ Application Site 4, 6 2-14 10 2-10 KVVP

Copper Conductor,

PVC Insulated and Sheathed, Braiding Shielded Control Cable

0.75, 1.0, 1.5, 2.5 2-61

Permanent installation indoors, incable ditches or plpes where shielding is required

Type Name /Section Area(mm2)/ No. Of core/ Application Site 4, 6 2-14 10 2-10 KVVP

Copper Conductor, PVC Insulated and Sheathed, Copper-tape Screened Control Cable 0.75, 1.0, 1.5, 2.5 4-10 Permanent installation indoors, incable ditches or plpes where shielding is required

Type Name /Section Area(mm2)/ No. Of core/ Application Site 4, 6 7-61

10 4-10 KVV

Copper Conductor, PVC Insulated and Sheathed, Steel-tape Armoured Control Cable 0.75, 1.0, 1.5, 2.5 7-61 Permanent installation indoors, incable ditches, pipes or under ground. Be able to bear stronger outer mechanical force

Type Name /Section Area(mm2)/ No. Of core/ Application Site 4, 6 4-14 10 4-14 KVVR

Copper Conductor, PVC Insulated and Sheathed Flexible Control Cable 0.5-2.5 4-61 Installation indoors where flexibility and movability are required KVVRP Copper Conductor, PVC Insulated and Sheathed, Braiding Shielded Flexible Control Cable 0.5, 0.75, 1.0 4-61 Installation indoors where flexibility shielding and movability are required

Type Name /Section Area(mm2)/ No. Of core/ Application Site 1.5, 2.5 4-48 KYJV

Copper Conductor, XLPE insulated and PVC Sheathed Control Cable 0.75, 1.0, 1.5, 2.5 2-16 Perm anent installation indoors, incable ditches or pipes

Type Name /Section Area(mm2)/ No. Of core/ Application Site 4, 6 2-14 10 2-10 KYJVP

Copper Conductor, XLPE Insulated, Braiding Shielded, PVC Sheathed Control Cable 0.75, 1.0, 1.5, 2.5 2-61 Permanent installation Indoors, Incable ditches or pipes where shielding is required

Type Name /Section Area(mm2)/ No. Of core/ Application Site 4, 6 2-14 10 2-10 KYJV22

Copper Conductor, XLPE Insulated, Steel-tape Armoured, PVC Sheathed Control Cable 0.75, 1.0, 1.5, 2.5 7-61 Permanent installation indoors, incable ditches, pipes or underground, Be able to bear stronger outer mechanical force

Type Name /Section Area(mm2)/ No. Of core/ Application Site 4, 6 4-14 10 4-10 KYJVP2

Copper Conductor, XLPE Insulated, Coppertape Screened, PVC Sheathed Control Cable 0.75, 1.0, 1.5, 2.5 7-61 Permanent installation indoors, incable ditches or pipes where shielding is required.

 

Type Name /Section Area(mm2)/ No. Of core/ Application Site 4, 6 4-14 10 4-10 KYJVR

Copper Conductor, XLPE insulated, PVC Sheathed Flexible Control Cable

0.5-2.5 4-61

Installation indoors where flexibility and movability are required

 

Type Name /Section Area(mm2)/ No. Of core/ Application Site KYJVRP

Copper Conductor, XLPE insulated, Braiding Shielded, PVC Sheathed Flexible Control Cable

0.5, 0.75, 1.0 4-61

Installation indoors where flexibility shielding and movability are required 1.5, 2.5 4-48

 

 

450/750V PVC sheath control cable XLPE insulation



Copyright Notice @ 2008-2022 ECBAY Limited and/or its subsidiaries and licensors. All rights reserved.